Gearbox> Helical Gearbox

7..THERMAL CAPACITY
7-2-1 Thermal Capacities - helical gear box - 1 stage

1.Features of KIP Gear Reducer
2.Designation and Reduction Ratio
2-1)
Designation and Symbols
2-2) Reduction Ratio
3.Selection
3-1)
How to select proper gear reducer
4. Service Factor
4-1)
Load Classification and Service Factor (Sf)
4-2)
Service factor for selection
5. Installation and operation
5-1) General
5-2) Installation
5-3) Operation
6. Maintenance 
7. Power Rating, Thermal Capacity and Dimension
7-1.Nominal Power Rating
1 stage  gearbox
2 stage  gearbox
3 stage  gearbox
4 stage  gearbox
7-2.Thermal Capacity
1 stage  gearbox
2 stage  gearbox
3 stage  gearbox
4 stage  gearbox
7-3.Dimensions
1 stage  gearbox
2 stage  gearbox
3 stage  gearbox
4 stage  gearbox
8.
Convenient technical formulas

description

Air
flow

Gear box Size

80

100

125

160

200

250

280

315

355

400

450

500

560

630

710

800

900

Thermal Capacities(kW)

Pr1

aircooling(small space)

wind
¡Ã0.5m/s

10

16

25

38

62

92

120

160

190

240

305

380

500

650

880

1160

1500

aircooling(outdoor)

wind
¡Ã1.4m/s

14

23

35

54

88

132

172

228

265

340

420

530

690

900

1170

1520

2000

aircooling(outdoor)

wind
¡Ã3.7m/s

19

30

47

73

116

175

225

300

350

455

570

710

900

1170

1520

1980

2570

Pr2

with
fan
cooling

1800

wind
¡Ã1.4m/s

-

33

52

80

127

190

245

330

350

500

600

-

-

-

-

-

-

wind
¡Ã3.7m/s

-

36

56

88

140

205

270

360

420

550

680

-

-

-

-

-

-

1200

wind
¡Ã1.4m/s

-

30

47

72

114

170

220

295

315

450

560

700

-

-

-

-

-

wind
¡Ã3.7m/s

-

33

50

79

125

185

242

324

380

495

615

770

-

-

-

-

-

900

wind
¡Ã1.4m/s

-

27

42

65

102

153

200

265

283

405

505

630

-

-

-

-

-

wind
¡Ã3.7m/s

-

30

45

71

112

168

220

290

340

445

555

690

-

-

-

-

-

Pr3

WITH
WATER
COOLING

wind
¡Ã0.5m/s

28

43

65

95

148

211

264

335

380

455

550

645

800

975

1230

1500

1800

wind
¡Ã1.4m/s

39

62

91

135

211

303

378

480

530

645

755

900

1100

1350

16401

1970

2400

wind
¡Ã3.7m/s

53

81

122

182

278

400

495

630

700

865

1025

1200

1440

1750

2130

2570

3080

Pr4

WITH
FAN
AND
WATER
COOLING

1800

wind
¡Ã0.5m/s

36

56

84

123

148

274

343

635

495

590

715

840

-

-

-

-

-

wind
¡Ã1.4m/s

58

80

118

175

274

394

491

625

690

840

980

1170

-

-

-

-

-

wind
¡Ã3.7m/s

79

105

158

236

360

520

645

820

830

1120

1330

1560

-

-

-

-

-

1200

wind
¡Ã0.5m/s

33

51

78

114

177

253

316

400

455

546

660

775

-

-

-

-

-

wind
¡Ã1.4m/s

47

74

109

162

253

363

453

575

635

775

905

1080

-

-

-

-

-

wind
¡Ã3.7m/s

64

97

146

218

333

480

595

755

840

1040

1230

1440

-

-

-

-

-

900

wind
¡Ã0.5m/s

31

47

71

104

162

232

290

368

420

500

605

710

-

-

-

-

-

wind
¡Ã1.4m/s

43

68

100

148

232

333

415

525

580

710

830

990

-

-

-

-

-

wind
¡Ã3.7m/s

58

89

134

200

305

440

545

690

770

950

1130

1245

-

-

-

-

-


Copyright(c) 1998, KIP Gear Drives. All rights reserved.

For Information, E-mail:kipdrive@gear.co.kr